LARA NOTICE
|
Number 05/2021
Issued on 12-05-2021
Valid until: UFN
Issued by LARA Team
The following Notice describes a problem with the interface between LARA and NM25.0 CHMI (CIAM). The issue could be observed when importing LARA’s AUP/UUP exported in .aca format into CIAM.
Issue: ACA incompatibility with NM25.0 | Affected software: LARA Server |
This incompatibility affects as well ACA import into LARA, when CHMI 17.0 (NM25.0) is used to produce the ACA file. Note that all current LARA releases (V3.0 / V3.1 / V3.2) are affected as, unfortunately, the backward compatibility with NM24.0 is not implemented in NM25.0. Note also that provision of AUP/UUP in ACA to CADF is considered as one of the backup solutions in the AMC-NM Agreement. |
|
Reproduction steps: 1) - Create an AUP in LARA. - Export the AUP in ACA. - Import the AUP into CIAM using CHMI 17.0. 2) - Create an AUP using CHMI 17.0 - Export the AUP in CHMI using ACA format. - Import the ACA AUP in LARA. |
|
Temporary workaround: As a temporary measure, the AUP Reader add-on can be used to generate the ACA file in NM25.0 format. Refer to the instructions described below for further guidance |
|
Fix: A software fix will be included in the future LARA V3.2.3 patch. |
The LARA AUP Reader is a LARA Add-On that allows to retrieve AUP/UUP information in multiple formats using either a simple Web Browser interface, either a command line.
The module requires the configuration of a Web Server using a PHP extension, and the wkhtmltopdf module if used for pdf generation.
Once the module is installed, the interface can be easily accessed via a standard Web Browser.
The use of the option “Extract AUP/UUP in ACA” allows to retrieve the plan under ACA format. In order to ensure that it will be aligned to NM25.0 format, you have to ensure that the “sql/AUP_ACA_AREAS.sql” query has an additional “\ “ in the SELECT statement, close to the TSA row:
SELECT ROW_NUMBER() OVER() "Nr", "Area/FBZ", "MNM FL", "MAX FL", "WEF", "TIL", 'TSA\' "Type",...
From a command line, you can simply execute the associated .bat command, or have it executed as a repetitive Scheduled Task (under MS-Windows, or equivalent .sh script or cronjob task under Linux).
In case of any questions please contact the LARA Team